Questions on Guarantee and Warranty Information
History of the Space Technology Hall of Fame
Harry T. Whelan, MD - Bleser Professor of Neurology and Pediatrics, Medical College of Wisconsin
Janis Eells, Ph.D. - Associate Professor, UW-Milwaukee College of Health Sciences
Margaret Wong-Riley, PhD Medical College of Wisconsin, Department of Cell Biology, Neurobiology & Anatomy
UW-Milwaukee College of Health Sciences 2005 Research Symposium
Safe Alternative to Over the Counter Pain Relievers (88KB pdf)
Pets: Help to Ease Their Pain (144KB pdf)
Revolutionary Discoveries in Sports Medicine (88KB pdf)
Chronic Pain Sufferers (96KB pdf)
Press Release: Quantum Devices Selected by NASA "Hallmarks of Success"

If you cannot view PDF files, you probably need to download Adobe Acrobat Reader.
Click here for a free download.


WARP 10 frequently asked questions

How often can I use the WARP 10® light?
NASA has defined that 8 joules (two 80 second doses) is the recommended limit for tissue absorption. The recommended time between 8 joule doses should be 12 hours. Much like a typical plant, the body needs time to make efficient use of the energy. The light will emit beneficial pain relief. There has never been any indication of the slightest side effect or unintended effect documented. This fact makes the WARP 10 ideal for chronic pain sufferers.

Can the WARP 10 help my (  your ailment here  )?
The WARP 10 is a hand held device used for the treatment of chronic pain by emitting energy in the Near-IR spectrum for the temporary relief of minor muscle and joint pain; arthritis and muscle spasm; relieving stiffness; promoting relaxation of muscle tissue; and temporarily increase local blood circulation where applied.

How close to the skin should I hold the WARP 10?
For best results, the WARP 10 should be touching the skin. Take your finger and point it to the central area of pain, and then hold the unit directly centered on that point.

I accidentally hit the ‘Stop’ button during my session. Why does it take so long for the delay light to go off?
The delay light will stay on until the normal timed cycle (80 seconds) has completed. You can then restart the mechanism. This feature was added as a safety feature for our Armed Forces. There is no battery usage during the timer’s click down.

Can you recommend a battery for usage?
Although you can use standard AA alkaline batteries to operate your WARP 10, we highly recommend the use of Nickel Metalhydride (NiMH) rechargeable batteries. This battery type almost doubles the amount of uses from the WARP 10 and in many cases the batteries can be recharged up to 1000 times, reducing operating costs to just pennies per dose.

What wavelength does the WARP 10 operate at?
The WARP 10 operates at a peak wavelength of 670nm.

How many LEDs does the WARP 10 have?
The WARP 10 utilizes 48 Chip mount LED die to provide 50 mW/cm2 over a 10cm2 diameter area. The total photon energy over the 10cm2 area is equal to 500 mW.

Is the WARP 10 FDA approved? What is the indicated use of the WARP 10?
The WARP 10 LED lighting system is FDA cleared for the consumer market, and is intended for the treatment of chronic pain by emitting energy in the Near-IR spectrum for the temporary relief of minor muscle and joint pain, arthritis and muscle spasm; relieving stiffness; promoting relaxation of muscle tissue; and to temporarily increase local blood circulation where applied.

I’ve seen press releases from NASA regarding this technology and light therapy, and most of the WARP 10s competitors link to the NASA technology. How does Quantum Devices, Inc. fit in?
Quantum Devices, Inc. developed the HEALS® (High Emissivity Aluminiferous Light-emitting Substrate) technology for NASA under a Small Business Innovative Research grant (SBIR). This technology is what allows Quantum Devices to reach the LED power levels of 50 mW/cm2 of energy that research shows is most beneficial for pain management. Although our competitors like to link to PR generated by NASA and other sources regarding the technology in order to gain credibility, it is important to remember that the WARP 10 is the only FDA cleared for market device that utilizes the HEALS technology developed for and used by NASA and DARPA.

What is PBMT?
Photobiomodulation Therapy (PBMT) is the process of modulating the organelles of the body with wavelength specific photon energy to increase respiratory metabolism, reduce the natural inflammatory response, accelerate recovery of injury or stress at the cellular level and increase circulation.

How much light energy is required for PBMT?
NASA research has determined that the radiant Power of Flux to produce reliable PBMT results must be equal to or greater than 50mW/cm2 (50 milliwatts per centimeter squared).

How long of a dose (exposure) is required for reliable PBMT?
NASA research has determined that the minimum Dose for the wavelength band from 650nm (nanameters) to 950nm, to be 4/joule/cm2 (one 80 second dose of WARP 10) at a radiant power of 50mW/cm2. They have also found that the effect seems to flatten out about 8 joule/cm2 (two 80 second doses) at a radiant power of 50mW/cm2.

What is Radiant Power or Radiant Flux?
Radiant Power is defined by the total power of radiation emitted by a source (lamp, Light Emitting Diode (LED), Laser, Black Body, etc.) transmitted through a surface or impinging upon a surface. Radiant Power is measured in watts (W).

What is Irradiance?
Describes the amount of radiant power per unit area.

What is a Joule?
Named for James Joule (1818-1889) English physicist who demonstrated the mechanical equivalent of heat. The joule provides a time dimension to energy or power. One joule is the equivalent of one watt of power radiated or dissipated for one second. i.e. A joule is a unit of energy equal to 1 watt second. Today, the most common household use of the term can be found on the surge suppressors we purchase to protect our computers and electrical equipment. A good rule of thumb is, the larger the number of joules, the more surge protection the unit provides. In PBMT the joule defines the total dose required to achieve the desired effect. All of the QDI PBMT products are specified in joules per cm2 to insure uniform dosage over the entire exposed area.

What is NIST?
The National Institute of Standards and Technology (NIST). Founded in 1901, NIST is a non-regulatory federal agency within the U.S. Commerce Department's Technology Administration, NIST's mission is to develop and promote measurement, standards and technology to enhance productivity, facilitate trade and improve the quality of life.

Why does the WARP 10 work?
Light must be absorbed for photochemistry to occur. A simple absorption spectrum (transmission spectrum) of the system under study will immediately tell one if a particular wavelength of light has a chance of producing a photobiological effect (Kendric C. Smith, Ph.D.).

Are lasers more effective than LEDs?
Unless your application requires the unique properties of microdot focusing, very high intensity, coherent radiation, the possibility of ultrashort pulses and a very narrow, monochromatic bandwidth, then a laser is just a very expensive light bulb (Kendric C. Smith, Ph.D.). You have to learn the "Facts of Light" (Kendric C. Smith, Ph.D.).

Kendric C. Smith, Ph. D., Professor Emeritus, Radiation Oncology (Radiation Biology) Stanford University, Stanford, CA: Laser Therapy Vol. 11-4 1999


Questions on Guarantee and Warranty Information

Do you offer a money back Guarantee?
Yes, we offer a 30 day money back guarantee. If you are not completely satisfied with the WARP 10TM it may be returned for a full refund of the purchase price (not including shipping and handling).

What is the Warranty?
QDI warrants the WARP 10® to be free from defects in workmanship and materials under normal use for a period of one (1) year from the date of shipment. QDI’s sole obligation under this warranty will be to repair or replace, at its option, products that prove to be defective during the warranty period. The foregoing shall be the sole warranty remedy. Except as set forth herein, seller makes no warranties, either expressed or implied, including the implied warranties of merchantability and fitness for a particular purpose. No warranty is provided if the product is modified without the express written consent of QDI. The seller shall not be liable in any event for incidental or consequential damage. This warranty is not assignable.

What is the return policy?
For either a guarantee or warranty return on your WARP 10, you must contact us for a return merchandise authorization number (RMA number). Call us at 608-924-3000, Monday through Friday, 8:00 AM to 5:00PM CST to obtain the RMA number from our customer service department. The unit can be returned to the following address: